Surfactant–albumin ratio

From WikiProjectMed
(Redirected from Surfactant-albumin ratio)
Jump to navigation Jump to search
Surfactant–albumin ratio

The surfactant–albumin ratio is a test for assessing fetal lung maturity.[1] The test, though no longer commercially available, used an automatic analyzer to measure the polarized fluorescent light emitted from a sample of amniotic fluid that had been challenged with a fluorescent probe that interacted competitively with both lecithin (phosphatidylcholine) and albumin in such a way that direct quantitative measurements of both substances could be attained.[2] Higher amounts of lecithin – in reference to albumin – is indicative of lung maturity (and thus survival of the baby). When this test was still used in practice, the Standards of Laboratory Practice set the threshold for lung maturity at 55 mg of lecithin per gram of albumin.[3]

References

  1. ^ Liu KZ, Shaw RA, Dembinski TC, Reid GJ, Ying SL, Mantsch HH (July 2000). "Comparison of infrared spectroscopic and fluorescence depolarization assays for fetal lung maturity". Am. J. Obstet. Gynecol. 183 (1): 181–7. doi:10.1067/mob.2000.105345. PMID 10920328.
  2. ^ Bernstein LH, Stiller R, Menzies C, McKenzie M, Rundell C (1995). "Amniotic fluid polarization of fluorescence and lecithin/sphingomyelin ratio decision criteria assessed". Yale J Biol Med. 68 (3–4): 101–17. PMC 2588960. PMID 8792602.{{cite journal}}: CS1 maint: multiple names: authors list (link)
  3. ^ Standards of Laboratory Practice: Guidelines for the Evaluation and Management of the Newborn. National Academy of Clinical Biochemistry, 1998.