File:T ratings oldest trick in the book 005.png

From WikiProjectMed
Jump to navigation Jump to search

Original file(18,673 × 27,768 pixels, file size: 6.6 MB, MIME type: image/png)

This file is from a shared repository and may be used by other projects. The description on its file description page there is shown below.

Summary

Warning The original file is very high-resolution. It might not load properly or could cause your browser to freeze when opened at full size.
Description
English: Innards of a bus duct, complete with double Mylar wrappings of each individual flatbar (bus bar). In the fire test leading to UL Through-Penetration Firestop Listing C-BJ-8028, the plastic wrappings, as well as the hollow plastic tube spacers that keep bus bar sandwiches apart, caught on fire. Since no firestop was permitted inside of the bus duct, this resulted in live fire going through the fire barrier on the inside of the bus duct. Internal firestops have to be included in the electrical testing to UL857 to be approved for use. But without the internal firestops, live fire and a steady stream of heat and smoke go through fire barriers and into adjacent fire compartments. Adhering to the electrical code, violates the building code.
Deutsch: Innenleben einer amerikanischen Stromschiene. Die einzelnen "Flachstähle", oder Leiter, entweder aus Aluminium oder Kupfer, sind mit Plastik (Mylar) umwickelt. Dies ist bis zu 130°C geprüft, was Kokolores ist, da Brandprüfungen um die 1100°C laufen. Diese Stromschiene kam bei einer Brandprüfung als Durchbruch zum Einsatz. Dies resultierte in der bauaufsichtlichen Zulassung UL Abschottungssystem C-BJ-8028. Eine innere Abschottung wurde seitens des Prüflabors verboten, da man sonst die elektrische Zulassung der Stromschiene gemäß UL857 verletzen würde. Das Plastik brennt selbstverständlich sehr gut. Durch Einhaltung elektrischer Vorschriften wird also gegen die generelle Bauvorschrift verstoßen, da in diesem Fall Feuer, Hitze und Rauch innen durch die Stromschiene durchgehen an der äußeren Abschottung vorbei und weiter in die abgewandte Seite. Einhaltung der Elektrovorschrift verstößt gegen die Bauvorschrift.
Date
Source Own work
Author Achim Hering

Licensing

I, the copyright holder of this work, hereby publish it under the following license:
w:en:Creative Commons
attribution
This file is licensed under the Creative Commons Attribution 4.0 International license.
You are free:
  • to share – to copy, distribute and transmit the work
  • to remix – to adapt the work
Under the following conditions:
  • attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.

Captions

Add a one-line explanation of what this file represents

Items portrayed in this file

depicts

8 August 2012

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current01:48, 29 September 2015Thumbnail for version as of 01:48, 29 September 201518,673 × 27,768 (6.6 MB)commons>Achim Hering{{Information |Description ={{en|1=Innards of a bus duct, complete with double Mylar wrappings of each individual flatbar (bus bar). In the fire test leading to [http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=XHEZ.C-BJ-...

There are no pages that use this file.