Talk:True RMS converter

From WikiProjectMed
Jump to navigation Jump to search

Thermal converters part is incorrect

The Thermal Converters part is uncorrect. Thermal converters are used by the NMIs for high precision voltage measurements. check e.g. http://www.ptb.de/en/org/2/22/222/spannung.htm - 15:03, 21 November 2007 134.169.64.140 Big text

I second this comment. NIST also uses thermal converters. http://www.nist.gov/pml/div684/grp06/acdc.cfm and in other Standard institutes. They are also quite precise with inaccuracies of less than 10ppm http://www.nikkohm.com/nikkohm_e_pdf/tvc_e20110701.pdf. Pelgv (talk) 00:52, 16 March 2016 (UTC)[reply]

fluke advertisement

why the fluke picture? how is it any different from the case of any multimeter in the world that is or isn't true rms? — Preceding unsigned comment added by 99.61.49.7 (talk) 19:42, 26 May 2012 (UTC)[reply]

What on grounded earth is a shankar effect?