Blood sugar level

From WikiProjectMed
(Redirected from Plasma glucose)
Jump to navigation Jump to search
Blood sugar level
Other names: Glycaemia, blood sugar concentration, blood glucose level
Suckale08 fig3 glucose insulin day.png
The fluctuation of blood sugar (red) and the sugar-lowering hormone insulin (blue) during the course of a day with three meal. One of the effects of a sugar-rich vs a starch-rich meal is highlighted.[1]
Reference rangeFasting: 3.9 to 5.6 mmol/L (70 and 100 mg/dL)[2]
After eating: Less than 11.1 mmol/L (200 mg/dL)[3]
Test ofGlucose[4]

Blood sugar level, also known as glycaemia, is a measure of amount of the sugar, glucose in the blood.[4] In someone who has not eaten, levels are generally 3.9 to 5.6 mmol/L (70 to 100 mg/dL).[2] Fasting levels greater than 7.0 mmol/L (126 mg/dL) on two separate occasions indicates diabetes.[2] Levels below 3.9 mmol/L (70 mg/dL) is known as hypoglycemia, though levels as low as 2.8 (50 mg/dL) may be normal in those without diabetes.[2][5] After eating levels may be as high as 11.1 mmol/L (200 mg/dL), though decrease to below 7.8 mmol/L (140 mg/dL) at two hours.[3] Newborns may have levels as low as 1.1 to 1.4 mmol/L (20 to 25 mg/dL) in the first few hours of life.[6]

There are different methods of measuring current blood sugar levels including glucometers and continuous glucose monitors.[7] An HbA1C test is a measure of average blood sugar levels over the last 2 to 3 month.[7] Inaccurate measurements may occur with poorly stored test strips, extremes of temperature, high elevation, and certain medications like vitamin C, dopamine, and acetaminophen.[8] Readings may be inaccurately high with sugar containing products on the skin, low hematocrit, high uric acid, or low oxygen levels.[8] Readings may be inaccurately low with poor circulation to the skin, high triglycerides, or high blood oxygen.[8]

The body tightly regulates blood glucose.[9] Glucose is stored in skeletal muscle and liver cells in the form of glycogen; in fasting, blood glucose is maintained at a constant level from these glycogen stores.[9] Glucose is critical for function, particularly of the brain which consumes about 60% of glucose in sedentary individuals.[9] It can be transported from the intestines or liver to other tissues via the blood.[9] Cellular uptake is primarily regulated by insulin, a hormone produced in the pancreas.[9] Approximately 4 grams is present in the blood of a 70 kg (154 lb) human.[9]

Normal values

Normal values may vary slightly between laboratories. Many factors affect blood sugar levels. The body's mechanism of blood sugar regulation (known as glucose homeostasis), when operating normally, restores the blood sugar level to a narrow range of about 4.4 to 6.1 mmol/L (79 to 110 mg/dL) (as measured by a fasting blood glucose test).[10]

Normal blood glucose level (tested while fasting) for non-diabetics is between 3.9 and 7.1 mmol/L (70 and 130 mg/dL). The average fasting plasma blood glucose level is about 5.5 mmol/L (100 mg/dL);[11][12] however, this fluctuates throughout the day. Blood sugar levels for those without diabetes and who are not fasting should be below 6.9 mmol/L (125 mg/dL).[13] The blood glucose target range for diabetics, according to the American Diabetes Association, should be 5.0–7.2 mmol/L (90–130 mg/dL) before meals and less than 10 mmol/L (180 mg/dL) two hours after meals (as measured by a blood glucose monitor).[14][15]

Despite widely variable intervals between meals or the occasional consumption of meals with a substantial carbohydrate load, human blood glucose levels tend to remain within the normal range. However, shortly after eating, the blood glucose level may rise, in non-diabetics, temporarily up to 7.8 mmol/L (140 mg/dL) or slightly more. For people with diabetes maintaining "tight diabetes control", the American Diabetes Association recommends a post-meal glucose level of less than 10 mmol/L (180 mg/dL) and a fasting plasma glucose of 3.9 to 7.2 mmol/L (70–130 mg/dL).[16]

The actual amount of glucose in the blood and body fluids is very small. In a healthy adult male of 75 kg (165 lb) with a blood volume of 5 L, a blood glucose level of 5.5 mmol/L (100 mg/dL) amounts to 5 g, equivalent to about a teaspoonful of sugar.[17] Part of the reason why this amount is so small is that, to maintain an influx of glucose into cells, enzymes modify glucose by adding phosphate or other groups to it.[citation needed]

Units

There are two way of measuring blood glucose levels: In The United Kingdom and commonwealth countries (Australia, Canada, India, etc.) and ex-USSR countries molar concentration, measured in mmol/L (millimoles per litre, or millimolar, abbreviated mM). In the United States, Germany, Japan and many other countries mass concentration is measured in mg/dL (milligrams per decilitre).[18]

Since the molecular weight of glucose C6H12O6 is 180, the difference between the two units is a factor of 18, so 1 mmol/L of glucose is equivalent to 18 mg/dL.[12]

Measurement

Sample source

Glucose testing in a fasting individual shows comparable levels of glucose in arterial, venous, and capillary blood. But following meals, capillary and arterial blood glucose levels can be significantly higher than venous levels. Although these differences vary widely, one study found that following the consumption of 50 grams of glucose, "the mean capillary blood glucose concentration is higher than the mean venous blood glucose concentration by 35%."[19][20]

Sample type

Glucose is measured in whole blood, plasma or serum. Historically, blood glucose values were given in terms of whole blood, but most laboratories now measure and report plasma or serum glucose levels. Because red blood cells (erythrocytes) have a higher concentration of protein (e.g., hemoglobin) than serum, serum has a higher water content and consequently more dissolved glucose than does whole blood. To convert from whole-blood glucose, multiplication by 1.14[21] has been shown to generally give the serum/plasma level.

To prevent contamination of the sample with intravenous fluids, particular care should be given to drawing blood samples from the arm opposite the one in which an intravenous line is inserted. Alternatively, blood can be drawn from the same arm with an IV line after the IV has been turned off for at least 5 minutes, and the arm has been elevated to drain infused fluids away from the vein. Inattention can lead to large errors, since as little as 10% contamination with a 5% glucose solution (D5W) will elevate glucose in a sample by 500 mg/dL or more. The actual concentration of glucose in blood is very low, even in the hyperglycemic.

Techniques

Two major methods have been used to measure glucose. The first, still in use in some places, is a chemical method exploiting the nonspecific reducing property of glucose in a reaction with an indicator substance that changes color when reduced. Since other blood compounds also have reducing properties (e.g., urea, which can be abnormally high in uremic patients), this technique can produce erroneous readings in some situations (5–15 mg/dL has been reported). The more recent technique, using enzymes specific to glucose, is less susceptible to this kind of error. The two most common employed enzymes are glucose oxidase and hexokinase.[22] Average blood glucose concentrations can also be measured. This method measures the level of glycated hemoglobin, which is representative of the average blood glucose levels over the last, approximately, 120 days.[22]

In either case, the chemical system is commonly contained on a test strip which is inserted into a meter, and then has a blood sample applied. Test-strip shapes and their exact chemical composition vary between meter systems and cannot be interchanged. Formerly, some test strips were read (after timing and wiping away the blood sample) by visual comparison against a color chart printed on the vial label. Strips of this type are still used for urine glucose readings, but for blood glucose levels they are obsolete. Their error rates were, in any case, much higher. Errors when using test strips were often caused by the age of the strip or exposure to high temperatures or humidity.[23] More precise blood glucose measurements are performed in a medical laboratory, using hexokinase, glucose oxidase, or glucose dehydrogenase enzymes.

Urine glucose readings, however taken, are much less useful. In properly functioning kidneys, glucose does not appear in urine until the renal threshold for glucose has been exceeded. This is substantially above any normal glucose level, and is evidence of an existing severe hyperglycemic condition. However, as urine is stored in the bladder, any glucose in it might have been produced at any time since the last time the bladder was emptied. Since metabolic conditions change rapidly, as a result of any of several factors, this is delayed news and gives no warning of a developing condition. Blood glucose monitoring is far preferable, both clinically and for home monitoring by patients. Healthy urine glucose levels were first standardized and published in 1965[24] by Hans Renschler.

A noninvasive method of sampling to monitor glucose levels has emerged using an exhaled breath condensate. However this method does need highly sensitive glucose biosensors.[25]

I. Chemical methods
A. Oxidation-reduction reaction
1. Alkaline copper reduction
Folin-Wu method Blue end-product
Benedict's method
  • Modification of Folin–Wu method for qualitative urine glucose.
Nelson–Somogyi method Blue end-product.
Neocuproine method * Yellow-orange color neocuproine[26]
Shaeffer–Hartmann–Somogyi
  • Uses the principle of iodine reaction with cuprous byproduct.
  • Excess I2 is then titrated with thiosulfate.
2. Alkaline Ferricyanide reduction
Hagedorn–Jensen Colorless end product; other reducing substances interfere with reaction.
B. Condensation
Ortho-toluidine method
Anthrone (phenols) method
  • Forms hydroxymethyl furfural in hot acetic acid
II. Enzymatic methods
A. Glucose oxidase
Saifer–Gerstenfeld method Inhibited by reducing substances like BUA, bilirubin, glutathione, ascorbic acid.
Trinder method
Kodak Ektachem
  • A dry chemistry method.
  • Uses spectrophotometry to measure the intensity of color through a lower transparent film.
Glucometer
  • Home monitoring blood glucose assay method.
  • Uses a strip impregnated with a glucose oxidase reagent.
B. Hexokinase

  • NADP as cofactor.
  • NADPH (reduced product) is measured in 340 nm.
  • More specific than glucose oxidase method due to G-6PO4, which inhibits interfering substances except when sample is hemolyzed.

Regulation

Pancreas regulates blood sugar level

The body's homeostatic mechanism keeps blood glucose levels within a narrow range. It is composed of several interacting systems, of which hormone regulation is the most important.[citation needed]

There are two types of mutually antagonistic metabolic hormones affecting blood glucose levels:

These hormones are secreted from pancreatic islets (bundles of endocrine tissues), of which there are four types: alpha (A) cells, beta (B) cells, Delta (D) cells and F cells. Glucagon is secreted from alpha cells, while insulin is secreted by beta cells. Together they regulate the blood-glucose levels through negative feedback, a process where the end product of one reaction stimulates the beginning of another reaction. In blood-glucose levels, insulin lowers the concentration of glucose in the blood. The lower blood-glucose level (a product of the insulin secretion) triggers glucagon to be secreted, and repeats the cycle.[28]

In order for blood glucose to be kept stable, modifications to insulin, glucagon, epinephrine and cortisol are made. Each of these hormones has a different responsibility to keep blood glucose regulated; when blood sugar is too high, insulin tells muscles to take up excess glucose for storage. Glucagon responds to too low of a blood glucose level; it informs the tissue to produce more glucose. Epinephrine prepares the muscles and respiratory system for activity in the case of a "fight and flight" response. Lastly, cortisol supplies the body with fuel in times of heavy stress.[29]

Abnormalities

The fasting blood glucose level, which is measured after a fast of 8 hours, is the most commonly used indication of overall glucose homeostasis, largely because disturbing events such as food intake are avoided. Conditions affecting glucose levels are shown in the table below. Abnormalities in these test results are due to problems in the multiple control mechanism of glucose regulation.[citation needed]

The metabolic response to a carbohydrate challenge is conveniently assessed by a postprandial glucose level drawn 2 hours after a meal or a glucose load. In addition, the glucose tolerance test, consisting of several timed measurements after a standardized amount of oral glucose intake, is used to aid in the diagnosis of diabetes.

Error rates for blood glucose measurements systems vary, depending on laboratories, and on the methods used. Colorimetry techniques can be biased by color changes in test strips (from airborne or finger-borne contamination, perhaps) or interference (e.g., tinting contaminants) with light source or the light sensor. Electrical techniques are less susceptible to these errors, though not to others. In home use, the most important issue is not accuracy, but trend. Thus if a meter / test strip system is consistently wrong by 10%, there will be little consequence, as long as changes (e.g., due to exercise or medication adjustments) are properly tracked. In the US, home use blood test meters must be approved by the federal Food and Drug Administration before they can be sold.

Finally, there are several influences on blood glucose level aside from food intake. Infection, for instance, tends to change blood glucose levels, as does stress either physical or psychological. Exercise, especially if prolonged or long after the most recent meal, will have an effect as well. In the typical person, maintenance of blood glucose at near constant levels will nevertheless be quite effective.[clarification needed]

Causes of abnormal levels
Persistent high Transient high Persistent low Transient low
Reference range, fasting blood glucose (FBG): 70–110 mg/dL
Diabetes mellitus Pheochromocytoma Insulinoma Acute alcohol ingestion
Adrenal cortical hyperactivity Cushing's syndrome Severe liver disease Adrenal cortical insufficiency Addison's disease Drugs: salicylates, antituberculosis agents
Hyperthyroidism Acute stress reaction Hypopituitarism Severe liver disease
Acromegaly Shock Galactosemia Several glycogen storage diseases
Obesity Convulsions Ectopic insulin production from tumors Hereditary fructose intolerance

High

Diabetes-prevalence.png

If blood sugar levels remain too high the body suppresses appetite over the short term. Long-term hyperglycemia causes many health problems including heart disease, cancer,[30] eye, kidney, and nerve damage.[31]

Blood sugar levels above 16.7 mmol/L (300 mg/dL) can cause fatal reactions. Ketones will be very high (a magnitude higher than when eating a very low carbohydrate diet) initiating ketoacidosis. The Mayo Clinic recommends emergency room treatment above 16.7 mmol/L (300 mg/dL) blood glucose.[citation needed] The most common cause of hyperglycemia is diabetes. When diabetes is the cause, physicians typically recommend an anti-diabetic medication as treatment. From the perspective of the majority of patients, treatment with an old, well-understood diabetes drug such as metformin will be the safest, most effective, least expensive, and most comfortable route to managing the condition.[32] Diet changes and exercise implementation may also be part of a treatment plan for diabetes.[citation needed]

Some medications may cause a rise in blood sugars of diabetics, such as steroid medications, including cortisone, hydrocortisone, prednisolone, prednisone, and dexamethasone.[33]

Low

If blood sugar levels drop too low, a potentially fatal condition called hypoglycemia develops. Symptoms may include lethargy, impaired mental functioning; irritability; shaking, twitching, weakness in arm and leg muscles; pale complexion; sweating; loss of consciousness.[citation needed]

Mechanisms that restore satisfactory blood glucose levels after extreme hypoglycemia (below 2.2 mmol/L or 40 mg/dL) must be quick and effective to prevent extremely serious consequences of insufficient glucose: confusion or unsteadiness and, in the extreme (below 0.8 mmol/L or 15 mg/dL) loss of consciousness and seizures. Without discounting the potentially quite serious conditions and risks due to or oftentimes accompanying hyperglycemia, especially in the long-term (diabetes or pre-diabetes, obesity or overweight, hyperlipidemia, hypertension, etc.), it is still generally more dangerous to have too little glucose – especially if levels are very low – in the blood than too much, at least temporarily, because glucose is so important for metabolism and nutrition and the proper functioning of the body's organs. This is especially the case for those organs that are metabolically active or that require a constant, regulated supply of blood sugar (the liver and brain are examples). In healthy individuals, blood glucose-regulating mechanisms are generally quite effective, and symptomatic hypoglycemia is generally found only in diabetics using insulin or other pharmacological treatment, and in starvation or severe malnutrition or malabsorption (of various causes), and conditions such as anorexia.[dubious ] Hypoglycemic episodes can vary greatly between persons and from time to time, both in severity and swiftness of onset. For severe cases, prompt medical assistance is essential, as damage to brain and other tissues and even death will result from sufficiently low blood-glucose levels.

Other animals

In general, ranges of blood sugar in common domestic ruminants are lower than in many monogastric mammals.[34] However this generalization does not extend to wild ruminants or camelids. For serum glucose in mg/dL, reference ranges of 42 to 75 for cows, 44 to 81 for sheep, and 48 to 76 for goats, but 61 to 124 for cats; 62 to 108 for dogs, 62 to 114 for horses, 66 to 116 for pigs, 75 to 155 for rabbits, and 90 to 140 for llamas have been reported.[35] A 90 percent reference interval for serum glucose of 26 to 181 mg/dL has been reported for captured mountain goats (Oreamnos americanus), where no effects of the pursuit and capture on measured levels were evident.[36] For beluga whales, the 25–75 percent range for serum glucose has been estimated to be 94 to 115 mg/dL.[37] For the white rhinoceros, the 95 percent range is 28 to 140 mg/dL.[38] For harp seals, a serum glucose range of 4.9 to 12.1 mmol/L [i.e. 88 to 218 mg/dL] has been reported; for hooded seals, a range of 7.5 to 15.7 mmol/L [i.e. about 135 to 283 mg/dL] has been reported.[39]

References

  1. Daly ME, Vale C, Walker M, Littlefield A, Alberti KG, Mathers JC (June 1998). "Acute effects on insulin sensitivity and diurnal metabolic profiles of a high-sucrose compared with a high-starch diet" (PDF). The American Journal of Clinical Nutrition. 67 (6): 1186–96. doi:10.1093/ajcn/67.6.1186. PMID 9625092.
  2. 2.0 2.1 2.2 2.3 "Indicator Metadata Registry Details". www.who.int. Archived from the original on 22 September 2022. Retrieved 8 December 2022.
  3. 3.0 3.1 Seery, Conor (15 January 2019). "Normal blood sugar ranges and blood sugar ranges for adults and children with type 1 diabetes, type 2 diabetes and blood sugar ranges to determine people with diabetes". Diabetes. Archived from the original on 3 December 2019. Retrieved 8 December 2022.
  4. 4.0 4.1 "Definition: Blood Glucose Level (for Parents) - Nemours KidsHealth". kidshealth.org. Archived from the original on 8 December 2021. Retrieved 9 December 2022.
  5. "Blood Glucose (Sugar) Test: Levels & What They Mean". Cleveland Clinic. Archived from the original on 18 August 2022. Retrieved 8 December 2022.
  6. Abramowski, A; Ward, R; Hamdan, AH (January 2022). "Neonatal Hypoglycemia". PMID 30725790. {{cite journal}}: Cite journal requires |journal= (help)
  7. 7.0 7.1 "Manage Blood Sugar". Centers for Disease Control and Prevention. 28 April 2021. Archived from the original on 5 November 2022. Retrieved 9 December 2022.
  8. 8.0 8.1 8.2 Erbach, M; Freckmann, G; Hinzmann, R; Kulzer, B; Ziegler, R; Heinemann, L; Schnell, O (September 2016). "Interferences and Limitations in Blood Glucose Self-Testing: An Overview of the Current Knowledge". Journal of diabetes science and technology. 10 (5): 1161–8. doi:10.1177/1932296816641433. PMID 27044519.
  9. 9.0 9.1 9.2 9.3 9.4 9.5 Wasserman DH (January 2009). "Four grams of glucose". American Journal of Physiology. Endocrinology and Metabolism. 296 (1): E11–21. doi:10.1152/ajpendo.90563.2008. PMC 2636990. PMID 18840763.
  10. "Screening for Type 2 Diabetes". Clinical Diabetes. 18 (2). 2000. Archived from the original on 2018-11-09. Retrieved 2022-10-23.
  11. Danaei, G (2 July 2011). "National, regional, and global trends in fasting plasma glucose and diabetes prevalence since 1980: systematic analysis of health examination surveys and epidemiological studies with 370 country-years and 2·7 million participants". The Lancet. 378 (9785): 31–40. doi:10.1016/S0140-6736(11)60679-X. PMID 21705069. S2CID 13951614.
  12. 12.0 12.1 What are mg/dL and mmol/L? How to convert? Glucose? Cholesterol? Archived 2018-08-28 at the Wayback Machine Advameg, Inc.
  13. Glucose test – blood Archived 2016-07-05 at the Wayback Machine. NIH – National Institutes of Health.
  14. Davidson NK, Moreland P (26 July 2011). "Living with diabetes blog". Mayo Clinic. Archived from the original on 14 May 2013.
  15. Schuster D (14 August 2008). "What Does 'Post-Meal (Or Post-Prandial) Blood Sugar' Mean And What Does It Tell You?". Ohio State University. Archived from the original on 31 October 2022. Retrieved 23 October 2022.
  16. American Diabetes Association (January 2006). "Standards of medical care in diabetes--2006". Diabetes Care. 29 Suppl 1 (Supplement 1): S4–42. doi:10.2337/diacare.29.s1.06.s4. PMID 16373931. S2CID 29740430. Archived from the original on 2012-04-29. Retrieved 2022-10-23. Standards of Medical Care – Table 6 and Table 7, Correlation between A1C level and Mean Plasma Glucose Levels on Multiple Testing over 2–3 months
  17. USDA National Nutrient Database for Standard Reference, Release 22 (2009)
  18. "Blood Glucose Monitor and Blood Glucose Meter - Blood Glucose Measurement Units FAQ". 6 July 2011. Archived from the original on 6 July 2011.
  19. Somogyi M (May 1948). "Studies of arteriovenous differences in blood sugar; effect of alimentary hyperglycemia on the rate of extrahepatic glucose assimilation" (PDF). The Journal of Biological Chemistry. 174 (1): 189–200. doi:10.1016/S0021-9258(18)57386-5. PMID 18914074. Archived (PDF) from the original on 2018-08-09. Retrieved 2022-10-23.
  20. Roe J. "Glucose Concentration Difference Between Arterial, Capillary, and Venous Blood". Best Thinking. Archived from the original on 4 December 2014.
  21. Cox DL, Nelson MM (2013). Lehninger principles of biochemistry (6th ed.). New York: W.H. Freeman. p. 950. ISBN 9781429234146.
  22. 22.0 22.1 Cox MM, Lehninger AL, Nelson DL (2017). Lehninger Principles of Biochemistry. New York: W.H. Freeman. pp. 248–49. ISBN 9781319117689.
  23. Ginsberg BH (July 2009). "Factors affecting blood glucose monitoring: sources of errors in measurement". Journal of Diabetes Science and Technology. 3 (4): 903–13. doi:10.1177/193229680900300438. PMC 2769960. PMID 20144340.
  24. Renschler HE, Weicker H, von Baeyer H (December 1965). "[The upper limit of glucose concentration in the urine of healthy subjects]". Deutsche Medizinische Wochenschrift. 90 (53): 2349–53. PMID 5851934.
  25. Tankasala, D; Linnes, JC (November 2019). "Noninvasive glucose detection in exhaled breath condensate". Translational Research. 213: 1–22. doi:10.1016/j.trsl.2019.05.006. PMC 6783357. PMID 31194942.
  26. Neocuproine MSDS Archived 2021-10-18 at the Wayback Machine. hazard.com
  27. Lehninger A, Nelson D, Cox M (2017). Lehininger Principles of Biochemistry. New York: W.H. Freedom. p. 934. ISBN 9781319117689.
  28. Tortora G (December 2016). Principles Anatomy and Physiology (15 ed.). New York: John Wiley & Sons, Inc. pp. Chapter 18. ISBN 9781119343738.
  29. Lehninger A, Nelson D, Cox M (2017). Lehninger Principles of Biochemistry (7th ed.). New York: W.H.Freeman. p. 930. ISBN 9781319117689.
  30. "Excess sugar linked to cancer". Science Daily. Archived from the original on 2018-11-23. Retrieved 2022-10-23.
  31. "Diabetic ketoacidosis - Symptoms and causes". Mayo Clinic. Archived from the original on 2018-03-07. Retrieved 2018-01-30.
  32. Consumer Reports Health Best Buy Drugs. "The Oral Diabetes Drugs: Treating Type 2 Diabetes" (PDF). Best Buy Drugs: 2. Archived (PDF) from the original on 15 June 2013. Retrieved 18 September 2012.
  33. "Steroid medications and diabetes fact sheet – NDSS". www.ndss.com.au. Archived from the original on 2022-06-28. Retrieved 2022-10-23.
  34. Eiler H (2004). "Endocrine glands". In Reese WO (ed.). Dukes' Physiology of Domestic Animals (12th ed.). Ithaca, NY: Comstock. pp. 621–69. ISBN 978-0801442384.
  35. Kahn CM, ed. (2005). Merck Veterinary Manual (9th ed.). Whitehouse Station: Merck & Co. ISBN 978-0911910506.
  36. Rice, C. G.; Hall, B. (2007). "Hematologic and biochemical reference intervals for mountain goats (Oreamnos americanus): effects of capture conditions". Northwest Science. 81 (3): 206. doi:10.3955/0029-344X-81.3.206. S2CID 56564674.
  37. Cornell LH, Duffield DS, Joseph BE, Stark B (April 1988). "Hematology and serum chemistry values in the beluga (Delphinapterus leucas)". Journal of Wildlife Diseases. 24 (2): 220–4. doi:10.7589/0090-3558-24.2.220. PMID 3373628.
  38. Seal, U. S.; Barton, R.; Mather, L.; Gray, C. W. (1976). "Baseline Laboratory Data for the White Rhinoceros (Ceratotherium simum simum)" (PDF). The Journal of Zoo Animal Medicine. 7 (1): 11–17. JSTOR 20094341. Archived (PDF) from the original on 2017-12-11. Retrieved 2022-10-23.
  39. Boily F, Beaudoin S, Measures LN (January 2006). "Hematology and serum chemistry of harp (Phoca groenlandica) and hooded seals (Cystophora cristata) during the breeding season, in the Gulf of St. Lawrence, Canada". Journal of Wildlife Diseases. 42 (1): 115–32. doi:10.7589/0090-3558-42.1.115. PMID 16699154. S2CID 21875860.

External links